Power Window Can Be Operated After Ignition Switch Is Turned Off Even If Operative Conditions Are Not Met
POWER WINDOW CAN BE OPERATED AFTER IGNITION SWITCH IS TURNED OFF EVEN IF OPERATIVE CONDITIONS ARE NOT METCIRCUIT DESCRIPTION
Power is supplied to the power window master switch and each regulator switch continuously for 45 seconds after the ignition switch is turned OFF unless the front doors have been opened so that the power window can be operated during this period. However, if either front door is opened or if a signal from any of the front door courtesy lamp switches is input to the ECU during 45 seconds, or if 45 seconds pass with nothing being done, power supply will stop thus disabling power window operation.
Wiring Diagram:
Step 1 - 3:
Step 4:
INSPECTION PROCEDURE