Water Thermo Switch Circuit
Disconnect water thermo switch connector from switch. If monitor lamp does not illuminate, check for E/L
control unit malfunction, water thermo switch or
relay malfunction, open circuit in wiring harness between water thermo switch and E/L control unit or
engine control unit terminal 1H (non-turbo) or 1I (turbo) malfunction.