ATF Thermoswitch
ATF THERMOSWITCHINSPECTION 1.
Remove the ATF thermoswitch.
2.
Place the switch in oil with a thermometer as shown, and heat it up gradually.
3.
Check the continuity of the terminals. If necessary replace the switch.
CONNECTION GUIDE FLUID TEMPERATURE CONTINUITY Above 150 ± 3°C (302 ± 37°F)
YES
Below 143°C (289°F)
NO