Coolant Temperature Sensor/Switch (For Computer): Testing and Inspection
WATER THERMOSWITCHTesting Water Thermoswitch:
INSPECTION 1.
Remove the Water thermoswitch.
2.
Place the switch in water with a thermometer and heat up the water gradually.
3.
Check the continuity of the terminals. If necessary, replace the switch.
CONNECTION GUIDE WATER TEMPERATURE CONTINUITY Below 65°C (149°F)
YES
Above 72 ± 5°C (162 ± 41°F)
NO