Variable Induction Control Actuator: Testing and Inspection
RemovalRemove the VRIS shutter valve actuator in the sequence described below.
Removal Sequence:
(1) Protector cover
(2) C-clip
(3) Vacuum hose
(4) Nuts screw
(5) VRIS shutter valve actuator
Inspection
1. Connect a vacuum pump tester to the actuator.
2. Apply vacuum and check that the rod is pulled into the actuator.
3. Replace if necessary.
Installation Sequence:
Installation
Install in the reverse order of removal.