Pinpoint Test 3
Flowchart No.3 Symptom Interior light does not illuminate [MX-6] (Spot light functions normally)
Possible Cause
^ Burnt interior light bulb
^ Damaged interior and spot light
^ Damaged CPU
^ Damaged door switch
^ Open or short circuit in wiring harness Poor connection of connector
Bulb Inspection:
Action Chart:
Step 1
Remove and check the interior light bulb.
Terminal Identification:
Action Chart:
Step 2
1. Remove the interior and spotlight.
2. Disconnect the interior and spotlight connector.
3. Check for continuity between terminal D (B) of the interior and spot light connector and ground.
Ohmmeter Connection:
Step 3
1. Remove the CPU from the joint box.
2. Connect a jumper wire between terminal 1E of the CPU connector on the joint box and ground.
3. Check for continuity between terminal B (G) of the interior and spot light connector and ground.
Ohmmeter Connection:
Action Chart:
Step 4
1. Open any door.
2. Check for continuity between terminal 1E of the CPU connector on the joint box and ground.
Ohmmeter Connection:
Reference:
Step 5
1. Remove the door switch.
2. Check for continuity between the terminals of the door switch.
3. If correct, repair the wiring harness. (CPU-door switch)