Battery: Testing and Inspection
Inspection
Battery discharge test
Terminal and cable
CAUTION
^ Because the battery is a maintenance-free battery, the fluid level need not be checked.
^ Do not remove the vent caps.
^ Be sure the top of the battery is clean. Clean it with baking soda and water if necessary.
1. Check the tightness of the terminals to ensure good electrical connections.
Tightening torque:
6.8 - 10.0 N.m {0.69 - 1.01 kgf.m, 5 - 7 ft.lbf}
2. Check for corroded and frayed battery cables. Clean or replace as necessary.
3. Check the rubber protector on the positive terminal for proper coverage.
4. Clean the terminals if necessary and coat them with grease.