UREA QUALITY SENSOR INSPECTION [SKYACTIV-D 2.2]
id0140z7826900
UREA QUALITY SENSOR TEMPERATURE INSPECTION
PID/DATA monitor inspection
1. Park the vehicle on level ground.
2. Verify the ambient temperature.
3. Connect the M-MDS to the DLC-2.
4. Switch the ignition ON (engine off).
5. Using the M-MDS, display the urea temperature (PID: S_UR_TANK_TMP) detected by the urea temperature sensor and the urea temperature detected by the urea quality sensor (PID: DEF_T) (See ON-BOARD DIAGNOSTIC TEST [PCM (SKYACTIV-D 2.2)].) (See ON-BOARD DIAGNOSTIC TEST [DOSING CONTROL UNIT (SKYACTIV-D 2.2)].)
6. Verify that the difference in values between PID S_UR_TANK_TMP and PID DEF_T is within ±6 °C.
UREA QUALITY SENSOR CONCENTRATION INSPECTION
PID/DATA monitor inspection
1. Replace with new AdBlue®. (See AdBlue® REPLACEMENT [SKYACTIV-D 2.2].)
2. Connect the M-MDS to the DLC-2.
3. Switch the ignition ON (engine off).
4. Using the M-MDS, display the urea tank concentration (PID: DEF_CON). (See ON-BOARD DIAGNOSTIC TEST [PCM (SKYACTIV-D 2.2)].)
5. Verify that the PID DEF_CON value is as specified.