No.1 UNABLE TO COMMUNICATE WITH GENERIC ELECTRONIC MODULE (GEM) [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]
id090361808600
1 |
Door glass does not operate even though various operations are performed |
---|---|
POSSIBLE CAUSE
|
• Power window main switch malfunction
• Power window motor malfunction
• Battery malfunction (low voltage)
• power window initialization procedure error
• Open circuit in wiring harness between power window main switch and BCM
• BCM malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
• Inspect the operation of the door glass by operating the power window main switch.
• Is the manual operation normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect the following parts, and repair or replace.
• Power window main switch
• Power window motor
• Battery (low voltage)
|
||
2
|
• Inspect the operation of the door glass by operating the power window main switch.
• Does the door glass operate in auto?
|
Yes
|
Go to the next step.
|
No
|
Perform the power window initialization procedure.
|
||
3
|
• Does the door lock/unlock normally?
|
Yes
|
Inspect the wiring harness between the power window main switch and the BCM.
If there is any malfunction, repair or replace the applicable part.
|
No
|
Replace the BCM.
|