NO.3 BSM OFF INDICATOR LIGHT ILLUMINATES CONTINUOUSLY [BLIND SPOT MONITORING (BSM) CONTROL MODULE CONNECTOR 8-PIN TYPE]
id0903n1990500
3
|
BSM OFF indicator light illuminates continuously
|
DESCRIPTION
|
• The BSM OFF indicator light illuminates for 4 s or more without the BSM OFF switch turning off after the ignition switch is turned to the ON position.
|
Possible Causes
|
• Malfunction in BSM OFF switch related parts
• Instrument cluster does not turn off BSM indicator light
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY DTCs
• Retrieve DTCs from the BSM control module (RH) and instrument cluster using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Go to the next step.
|
||
2
|
INSPECT IF MALFUNCTION IS IN BSM OFF SWITCH OR INSTRUMENT CLUSTER
• Monitor the BSM control module (RH) PID BSM_OFF_IL using the M-MDS.
• Turn the BSM OFF switch on and off.
• Does the PID BSM_OFF_IL monitoring value turn on and off according to the BSM OFF switch operation?
|
Yes
|
Go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT BSM OFF SWITCH
• Inspect the BSM OFF switch.
• Is the BSM OFF switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the BSM OFF switch.
|
||
4*
|
INSPECT BSM OFF SWITCH RELATED WIRING HARNESS
• Inspect for an open circuit in the following:
• Is a short to ground detected?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Replace the BSM control module (RH).
|
||
5
|
INSPECT IF MALFUNCTION IS IN INSTRUMENT CLUSTER OR BSM CONTROL MODULE (RH)
• Turn on the BSM OFF indicator light using check code 26 of the instrument cluster input/output check mode function.
• Does the BSM OFF indicator light illuminate?
|
Yes
|
Replace the BSM control module (RH).
|
No
|
Replace the instrument cluster.
|