INDICATOR UNIT INSPECTION
id092200705400
Terminal Voltage Inspection
1. Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the sensor cover. (See SENSOR COVER REMOVAL/INSTALLATION.)
3. Connect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)
4. Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
Terminal Voltage Table (Reference)
a30zzw00001762
|
Terminal |
Signal name |
Connected to |
Measurement conditions |
Voltage (V) |
Inspection item(s) |
|
---|---|---|---|---|---|---|
A
|
IG
|
• IG1 relay No.2
• F47 15A fuse
|
Main power ON (READY off or on)
|
B+
|
• F47 15A fuse
• IG1 relay No.2
• Related wiring harness
|
|
Main power OFF or to ACC
|
1.0 or less
|
|||||
B
|
—
|
—
|
—
|
—
|
—
|
|
C
|
—
|
—
|
—
|
—
|
—
|
|
D*1
|
REVERSE
|
Auto-dimming rearview mirror
|
Selector lever position is in R position
|
B+
|
• Auto-dimming rearview mirror
• Related wiring harness
|
|
E
|
—
|
—
|
—
|
—
|
—
|
|
F
|
GND
|
Body ground
|
Under any condition
|
Approx. 0
|
• GND point
• Related wiring harness
|
|
G
|
LIN_CBCM
|
Body control module (BCM)
|
Because this terminal is for communication, determination using terminal voltage inspection is not possible.
|
|||
H
|
—
|
—
|
—
|
—
|
—
|
|
I
|
—
|
—
|
—
|
—
|
—
|
|
J
|
—
|
—
|
—
|
—
|
—
|
|
K
|
—
|
—
|
—
|
—
|
—
|
|
L
|
—
|
—
|
—
|
—
|
—
|
|
M
|
—
|
—
|
—
|
—
|
—
|
|
N
|
—
|
—
|
—
|
—
|
—
|
|
O
|
—
|
—
|
—
|
—
|
—
|
|
P
|
—
|
—
|
—
|
—
|
—
|