DETERMINING SHORT TO POWER SUPPLY LOCATION (CAN-BUS No.8) [R.H.D.]


id100226004700

Caution
•  Perform the following malfunction diagnosis only when it is diagnosed with a short to power supply by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [R.H.D.].)

System Wiring Diagram

a30zzw00006616

Determination Procedure

Caution
•  When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
•  When inspecting the connector, touch it with a paper clip or similar thin pin without directly inserting a tester probe into the terminal.
•  Disconnect the negative lead-acid battery terminal before performing any work that requires handling of connectors.

Step

Inspection

Action

1
INSPECT CAN LINE BETWEEN CONNECTOR C-19 AND BODY CONTROL MODULE (BCM) FOR SHORT TO POWER SUPPLY
•  Switch the main power OFF.
•  Disconnect the negative lead-acid battery terminal.
•  Disconnect the connector C-19.
•  Connect the negative lead-acid battery terminal.
•  Switch the main power ON (READY off).
•  Measure the voltage at body control module (BCM) terminals 3V and 3U.
•  Is the voltage between 1.5—3.5 V?
Yes
Go to Step 3.
No
Go to the next step.
2
INSPECT BODY CONTROL MODULE (BCM) FOR SHORT TO POWER SUPPLY
•  Switch the main power OFF.
•  Disconnect the negative lead-acid battery terminal.
•  Disconnect the connector 3 which has body control module (BCM) terminals 3V and 3U.
•  Connect the connector C-19.
•  Connect the negative lead-acid battery terminal.
•  Switch the main power ON (READY off).
•  Measure the voltage at body control module (BCM) terminals 3V and 3U (wiring harness side).
•  Is the voltage between 1.5—3.5 V?
Yes
Replace the body control module (BCM) because there is a short to the power supply in the body control module (BCM).
No
Repair or replace the wiring harness between the body control module (BCM) and connector C-19 because the wiring harness is shorted to the power supply.
3
INSPECT EMERGENCY CALL UNIT FOR SHORT TO POWER SUPPLY
•  Switch the main power OFF.
•  Disconnect the negative lead-acid battery terminal.
•  Disconnect the emergency call unit connector.
•  Connect the connector 3 which has body control module (BCM) terminals 3V and 3U.
•  Connect the negative lead-acid battery terminal.
•  Switch the main power ON (READY off).
•  Measure the voltage at body control module (BCM) terminals 3V and 3U.
•  Is the voltage between 1.5—3.5 V?
Yes
Replace the emergency call unit because there is a short to the power supply in the emergency call unit.
No
Repair or replace the wiring harness between the emergency call unit and connector C-19 because the wiring harness is shorted to the power supply.