STEP
|
INSPECTION
|
ACTION
|
1
|
• Do the following symptoms occur concurrently?
-
- Engine flares up or slips during acceleration
-
- Engine flares up or slips when shifting
|
Yes
|
Go to No.14 "ENGINE FLARES UP OR SLIPS WHEN UPSHIFTING OR DOWNSHIFTING", or No.15 "ENGINE FLARES UP OR SLIPS WHEN ACCELERATING VEHICLE".
|
No
|
Go to the next step.
|
2
|
• Access the following PCM PIDs using the M-MDS.
-
- RPM
-
- APP
-
- TP
-
- ECT
-
- ENG_TRQ
• Are PIDs value normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect and repair suspected PID related part.
|
3
|
• Stop the engine.
• Inspect line pressure control solenoid.
• Is the normal?
|
Yes
|
Inspect the ATF condition.
• If a large amount of metal specks are found, replace the transmission.
• If a large amount of metal specks are not found, replace the control valve body.
|
No
|
Replace the control valve body.
|
4
|
• Verify test results.
-
- If normal, return to the diagnostic index to service any additional symptoms.
-
- If malfunction remains, inspect the related Service Information and perform repair or diagnosis.
-
• If the vehicle is repaired, troubleshooting completed.
-
• If the vehicle is not repaired or additional diagnostic information is not available, replace the TCM.
|