DTC B1D99:94 [RETRACTABLE HARDTOP CONTROL MODULE]
id0902r4074600
Description |
Error signal received from front roof link motor (RH) |
---|---|
Detection condition
|
• The retractable hardtop control module receives a signal from the front roof link motor (RH) while the front roof link motor (RH) is not operating.
|
Fail-safe
|
• Stops retractable hardtop operation
|
Possible cause
|
• Short to power supply in wiring harness between the following terminals:
• Front roof link motor (RH) malfunction
• Retractable hardtop control module malfunction
|
![]() |
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY OTHER RETRACTABLE HARDTOP CONTROL MODULE DTCs
• Clear the DTC for the retractable hardtop control module using the M-MDS.
• Retrieve the retractable hardtop control module DTCs using the M-MDS.
• Is the DTCs U3000:44/U3000:45/U3000:49 displayed?
|
Yes
|
Replace the retractable hardtop control module, then go to Step 4.
|
No
|
Go to the next step.
|
||
2
|
INSPECT FRONT ROOF LINK MOTOR (RH) CIRCUIT FOR SHORT TO POWER SUPPLY
• Switch the ignition off.
• Disconnect the negative battery terminal.
• Disconnect the retractable hardtop control module and front roof link motor (RH) connectors.
• Connect the negative battery terminal.
• Switch the ignition ON (engine off or on).
• Measure the voltage at the following terminals (wiring harness-side):
• Is the voltage 0 V?
|
Yes
|
Go to the next step.
|
No
|
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
• Retractable hardtop control module terminal 3F and front roof link motor (RH) terminal A
• Retractable hardtop control module terminal 3J and front roof link motor (RH) terminal E
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness which has a short to power supply.
Go to Step 4.
|
||
3
|
INSPECT FRONT ROOF LINK MOTOR (RH)
• Inspect the front roof link motor (RH).
(See ROOF LINK MOTOR INSPECTION.)
• Is the front roof link motor (RH) normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the front roof link motor (RH), then go to the next step.
|
||
4
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Always reconnect all disconnected connectors.
• Connect the negative battery terminal.
• Clear the DTC for the retractable hardtop control module using the M-MDS.
• Retrieve the retractable hardtop control module DTCs using the M-MDS.
• Is the same Pending DTC present?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the retractable hardtop control module.
Go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|