DTC U3003:17 [RETRACTABLE HARDTOP CONTROL MODULE]
id0902r4079700
Description |
Retractable hardtop control module high power supply voltage input |
---|---|
Detection condition
|
• The retractable hardtop control module power supply circuit voltage of 17.5 V or more is detected with the ignition switched ON (engine off or on).
|
Fail-safe
|
• Stops retractable hardtop operation
|
Possible cause
|
• PCM stores DTCs
• Battery malfunction
• Generator malfunction
• Retractable hardtop control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY OTHER RETRACTABLE HARDTOP CONTROL MODULE DTCs
• Clear the DTC for the retractable hardtop control module using the M-MDS.
• Retrieve the retractable hardtop control module DTCs using the M-MDS.
• Is the DTCs U3000:44/U3000:45/U3000:49 displayed?
|
Yes
|
Replace the retractable hardtop control module, then go to Step 5.
|
No
|
Go to the next step.
|
||
2
|
VERIFY PCM DTCs
• Retrieve the PCM DTCs using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
3
|
INSPECT BATTERY
• Inspect the battery.
(See BATTERY INSPECTION.)
• Is the battery normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the battery, then go to Step 5.
|
||
4
|
INSPECT GENERATOR
• Inspect the generator.
• Is the generator normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the generator, then go to the next step.
|
||
5
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the retractable hardtop control module using the M-MDS.
• Retrieve the retractable hardtop control module DTCs using the M-MDS.
• Is the same Pending DTC present?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the retractable hardtop control module.
Go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|