ROOF LINK LIMIT SWITCH INSPECTION


id091600114200

1.  Using the retractable hardtop switch, keep the retractable hardtop half-open.

amxzzw00004091

2.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

3.  Remove the quarter trim. (See QUARTER TRIM REMOVAL/INSTALLATION.)

4.  Disconnect the connectors.

amxzzw00004272

5.  Verify that the continuity between the roof link limit switch terminals is as indicated in the table.

amxzzw00004205
•  If not as indicated in the table, replace the roof link limit switch. (See ROOF LINK LIMIT SWITCH REMOVAL/INSTALLATION.)
amxzzw00004206