Diagnostic procedure
| 
  
STEP
 
 | 
    
  
INSPECTION
 
 | 
    
  
ACTION
 
 | 
|
|---|---|---|---|
| 
  
1
 
 | 
    
 
VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
  
• Has FREEZE FRAME DATA been recorded?
 
 | 
    
  
Yes
 
 | 
    
  
Go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Record the FREEZE FRAME DATA on the repair order, then go to the next step.
 
 | 
||
| 
  
2
 
 | 
    
 
VERIFY RELATED REPAIR INFORMATION AVAILABILITY
  
• Verify related service repair information availability.
 
 
• Is any related repair information available?
 
 | 
    
  
Yes
 
 | 
    
  
Perform repair or diagnosis according to the available repair information.
 
 
• If the vehicle is not repaired, go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Go to the next step.
 
 | 
||
| 
  
3
 
 | 
    
 
INSPECT IGNITION COIL NO.3 FOR POOR CONNECTION
  
• Turn the ignition switch off.
 
 
• Disconnect the ignition coil No.3 connector.
 
 
• Inspect for poor connection (such as damaged, pulled-out pins, and corrosion).
 
 
• Is there any malfunction?
 
 | 
    
  
Yes
 
 | 
    
  
Repair or replace the terminal, then go to Step 10.
 
 | 
| 
  
No
 
 | 
    
  
Go to the next step.
 
 | 
||
| 
  
4
 
 | 
    
 
INSPECT IGNITION COIL NO.3 ELECTRICAL MALFUNCTION
  
• Inspect ignition coil No.3.
 
 
 
• Is ignition coil No.3 normal?
 
 | 
    
  
Yes
 
 | 
    
  
Go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Replace the ignition coil No.3, then go to Step 10.
 
 
 | 
||
| 
  
5
 
 | 
    
 
INSPECT CONTROL CIRCUIT FOR SHORT TO POWER
  
• Turn the ignition switch to the ON position (Engine off).
 
 
• Measure the voltage between following terminal and body ground: 
 
 
• Is the voltage B+?
 
 | 
    
  
Yes
 
 | 
    
  
Repair or replace the wiring harness, then go to Step 10.
 
 | 
| 
  
No
 
 | 
    
  
Go to the next step.
 
 | 
||
| 
  
6
 
 | 
    
 
INSPECT POWER CIRCUIT FOR OPEN CIRCUIT
  
• Turn the ignition switch off.
 
 
• Inspect for continuity between the following terminals:
 
 
• Is there continuity?
 
 | 
    
  
Yes
 
 | 
    
  
Go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Repair or replace the wiring harness, then go to Step 10.
 
 | 
||
| 
  
7
 
 | 
    
 
INSPECT PCM FOR POOR CONNECTION
  
• Turn the ignition switch off.
 
 
• Disconnect the PCM connector.
 
 
• Inspect for poor connection (such as damaged, pulled-out pins, and corrosion).
 
 
• Is there any malfunction?
 
 | 
    
  
Yes
 
 | 
    
  
Repair the terminal, then go to Step 10.
 
 | 
| 
  
No
 
 | 
    
  
Go to the next step.
 
 | 
||
| 
  
8
 
 | 
    
 
INSPECT CONTROL CIRCUIT MALFUNCTION FOR OPEN CIRCUIT
  
• Inspect for continuity between the following terminals:
 
 
• Is there continuity?
 
 | 
    
  
Yes
 
 | 
    
  
Go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Repair or replace the wiring harness, then go to Step 10.
 
 | 
||
| 
  
9
 
 | 
    
 
INSPECT GROUND CIRCUIT MALFUNCTION FOR OPEN CIRCUIT
  
• Inspect for continuity between the following terminals:
 
 
• Is there continuity?
 
 | 
    
  
Yes
 
 | 
    
  
Go to the next step.
 
 | 
| 
  
No
 
 | 
    
  
Repair or replace the wiring harness, then go to Step 10.
 
 | 
||
| 
  
10
 
 | 
    
 
VERIFY TROUBLESHOOTING OF DTC P0353 COMPLETED
  
• Make sure to reconnect all disconnected connectors.
 
 
• Clear the DTC using the WDS or equivalent.
 
 
• Perform the KOER self-test.
 
 
(See KOEO/KOER SELF TEST [ZY].)
 
 
• Is the same DTC present?
 
 | 
    
  
Yes
 
 | 
    
  
Replace the PCM, then go to the next step.
 
 
 | 
| 
  
No
 
 | 
    
  
Go to the next step.
 
 | 
||
| 
  
11
 
 | 
    
 
VERIFY AFTER REPAIR PROCEDURE
  
• Perform the "AFTER REPAIR PROCEDURE".
 
 
(See AFTER REPAIR PROCEDURE [ZY].)
 
 
• Are any DTCs present?
 
 | 
    
  
Yes
 
 | 
    
  
Go to applicable DTC troubleshooting.
 
 
(See DTC TABLE [ZY].)
 
 | 
| 
  
No
 
 | 
    
  
Troubleshooting completed.
 
 | 
||