HOLD SWITCH INSPECTION


id051700809000

1.  Disconnect the selector lever component connector.

(1)  Disconnect the negative battery cable.
(2)  Remove the side wall. (See SIDE WALL REMOVAL/INSTALLATION.)
(3)  Remove the front console component. (See FRONT CONSOLE COMPONENT REMOVAL/INSTALLATION.)
(4)  Disconnect the selector lever component connector.

L.H.D.

am2zzw00001181

R.H.D.

am2zzw00001013

2.  Verify continuity as indicated in the table.

Type A

am2zzw00003644

Type B

am2zzw00003645
•  If there is any malfunction, replace the selector lever. (See AUTOMATIC TRANSAXLE SHIFT MECHANISM REMOVAL/INSTALLATION.)

HOLD switch specification

Test Condition

Type A

Type B

HOLD switch is released
There is no continuity between terminals C and D.
There is no continuity between terminals A and B.
HOLD switch is depressed
There is continuity between terminals C and D.
There is continuity between terminals A and B.