DTC B1A84:51/U2100:00 [INSTRUMENT CLUSTER]
id0902e8999800
DTCs B1A84:51, U2100:00 |
Instrument cluster configuration error |
---|---|
Detection Condition
|
• Instrument cluster detects the configuration error.
• Configuration setting has not been performed.
|
Possible Causes
|
• Instrument cluster configuration not implemented.
• Instrument cluster configuration error
• Instrument cluster malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION
• Perform the instrument configuration using the M-MDS.
• Clear the DTC using the M-MDS.
• Perform the instrument cluster DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Perform the instrument cluster configuration again, then go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
VERIFY TROUBLESHOOTING COMPLETED
• Clear the DTC using the M-MDS.
• Perform the instrument cluster DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|