NO.1 KEYLESS ENTRY SYSTEM DOES NOT OPERATE NORMALLY [KEYLESS ENTRY SYSTEM]


id0903d2832300

•  When performing an asterisked (*) troubleshooting inspection, slightly shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, verify that the connectors, terminals and wiring harnesses are connected correctly and undamaged.

1
Keyless entry system does not operate normally
DESCRIPTION
•  Malfunction in door lock linkage system, or BCM
POSSIBLE CAUSE
•  Malfunction in BCM power supply
―  Open circuit in IG1 and/or B+ power supply circuit
―  Open or short circuit in ground circuit
―  BCM malfunction
•  Malfunction in key reminder switch related circuit
―  key reminder switch malfunction
•  Malfunction in door latch switch signal circuit
―  Open or short circuit in wiring between BCM and door latch switch
―  Door latch switch malfunction
•  Malfunction in trunk lid/liftgate latch switch signal circuit
―  Open or short circuit in wiring between BCM and trunk lid/liftgate lid latch switch
―  Trunk lid/liftgate latch switch malfunction
•  Malfunction in door lock/unlock signal circuit
―  Door lock actuator malfunction
―  Open or short circuit in wiring between BCM and door lock actuator
•  Malfunction in turn light signal circuit
―  BCM malfunction
―  Open or short circuit wiring between BCM and each turn signal light

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT FOR MALFUNCTION IN BCM POWER SUPPLY CIRCUIT OR ELSEWHERE
•  Did any of the following items operate during the keyless entry system operation inspection?
―  All doors lock/unlock
―  Hazard warning light flashes
Yes
Go to the next step.
No
Inspect the connection of the BCM connectors, and go to Step 4.
2
INSPECT FOR MALFUNCTION IN KEY REMINDER SWITCH OR ELSEWHERE
•  Did the following item operate during the keyless entry system operation inspection?
―  All doors lock/unlock
Yes
Go to the next step.
No
Go to Step 9.
3
INSPECT FOR MALFUNCTION IN DOOR LOCK ACTUATOR OR ELSEWHERE
•  Did the following item operate during the keyless entry system operation inspection?
―  Hazard warning light flashes
Yes
Go to the next step.
No
Go to Step 11.
*4
INSPECT BCM POWER SUPPLY CIRCUIT
•  Are the BCM power supply and voltage normal?
―  IG1 signal (terminal 4T)
―  B+ signal (terminal 3J, 5B, 4S)
Yes
Go to the next step.
No
•  Inspect for burnt fuse.
•  Inspect the power supply system wiring harness for an open or short circuit.
•  Then go to Step 14.
*5
INSPECT BCM GROUND CIRCUIT
•  Is the BCM ground voltage normal?
―  1.0 V or less (terminal 2N, 4B)
Yes
Go to the next step.
No
Inspect the ground system wiring harness for open circuit.
Then go to Step 14.
*6
INSPECT IF MALFUNCTION IS IN DOOR , TRUNK LID/ LIFTGATE LATCH SWITCH SIGNALS OR ELSEWHERE
•  Monitor following BCM (door, trunk lid/liftgate latch switch) PID using the M-MDS.
―  TR/LG_SW (Trunk lid/liftgate latch switch)
―  DRSW_P (Passenger’s door latch switch)
―  DRSW_D (Driver’s door latch switch)
―  DRSW_LR (Rear door latch switch (LH))
―  DRSW_RR (Rear door latch switch (RH))
•  Are monitored PID values normal?
Yes
Go to Step 8.
No
Go to the next step.
*7
INSPECT DOOR, TRUNK LID/ LIFTGATE LATCH SWITCH SIGNAL VOLTAGES
•  Are the wiring harness between the BCM and each door, trunk lid/liftgate latch switch normal?
―  Inspect each terminal (6G, 6H, 6K, 6E, 6F) under the following conditions.
Door latch switches (Terminal 6G, 6H, 6K, 6E)
•  Door closed: 1.0 V or less
•  Door open: Approx. 4.5V
Trunk lid/liftgate latch switch (Terminal 6F):
•  Trunk lid/liftgate closed: B+
•  Trunk lid/liftgate open: 1.0 V or less
Yes
Go to the next step.
No
•  Inspect for open or short circuit in wiring harness between BCM and suspected door latch/trunk lid/liftgate latch switch.
―  If wiring harness is normal, inspect suspect door latch/trunk lid/liftgate latch switch.
―  If wiring harness malfunction, repair or replace wiring harness.
Then go to Step 14.
8
INSPECT KEY REMINDER SWITCH
•  Measure the voltage at the following BCM terminals:
―  Key reminder switch signal (terminal 2J)
ON (Key inserted ignition key cylinder):B+
OFF (Key removed ignition key cylinder): 1.0 V or less
•  Is the key reminder switch normal?
Yes
Replace the BCM.
No
Replace the key reminder switch, then go to Step 14.
*9
INSPECT IF MALFUNCTION IS IN DOOR LOCK ACTUATOR, BCM GROUND CIRCUIT OR ELSEWHERE
•  Measure the voltage at the BCM terminals 5O, 5M while operating the transmitter.
―  Driver-side door locked: 1.0 V or less → B+→ 1.0 V or less (5O terminal)
―  Driver-side door unlocked: 1.0 V or less → B+→ 1.0 V or less (5M terminal)
•  Is the voltage as above?
Yes
Go to the next step.
No
•  Inspect the wiring harness between BCM and the door lock actuator for an open or short circuit.
•  Inspect the door lock actuator.
•  Then go to Step 14.
10
INSPECT DOOR LOCK LINKAGE
•  Operate the key cylinder and verify the door locks and unlock manually.
•  Does every door lock system work?
Yes
Go to step 12.
No
Inspect the door lock linkage then go to Step 14.
*11
INSPECT FOR MALFUNCTION IN THEFT-DETERRENT SYSTEM OR ELSEWHERE
•  Is the theft-deterrent system equipped?
Yes
Go to the next step.
No
Go to step 13.
12
INSPECT HOOD LATCH SWITCH AND TRUNK/LIFTGATE SIGNAL
•  Monitor following BCM PID using the M-MDS.
―  TR/LG_SW (trunk lid/liftgate latch switch)
―  HOOD_SW (hood latch switch)
•  Are monitored PID values ON (open)?
Yes
Normal operation (Hazard warning light flashing on vehicles with theft-deterrent system operates in conjunction with theft-deterrent system).
No
Go to the next step.
*13
INSPECT TURN LIGHT SIGNAL CIRCUIT
•  Measure voltage at the BCM terminals 5C, 3L (right side turn signal), 5E, 3K (left side turn signal) while operating hazard and/or turn signal on.
•  Are the terminal voltages are alternated between 1.0V or less and B+?
Yes
Verify the malfunction symptom again.
No
•  Inspect the wiring harnesses between the BCM and each turn light for a short circuit.
•  Inspect each turn light.
•  If these items are normal, replace the BCM.
*14
REINSPECT MALFUNCTION SYMPTOM AFTER REPAIR
•  Does the keyless entry system operate properly?
Yes
Troubleshooting completed.
Explain repairs to the customer.
No
Reinspect the malfunction symptoms, then repeat from Step 1 if the malfunction recurs.