PURGE SOLENOID VALVE INSPECTION[L3 Turbo]


id0116b4800900


Airflow Inspection

Note
•  Perform the following test only when directed.

1.  Remove the battery cover. (SeeBATTERY REMOVAL/INSTALLATION[L3 Turbo].)

2.  Disconnect the negative battery cable.

3.  Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION[L3 Turbo].)

4.  Inspect airflow between the ports under the following conditions.

•  If not as specified, replace the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION[L3 Turbo].)
•  If as specified, carry out the “Circuit Open/Short Inspection”.
am3zzw00003544
acxuuw00000046


Circuit Open/Short Inspection

1.  Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION[L3 Turbo].)

2.  Inspect the following wiring harnesses for an open or short circuit (continuity check).

acxuuw00000047
am3zzw00003610
acxuuw00000048

Open circuit
•  If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
―  Purge solenoid valve terminal A and main relay terminal A
―  Purge solenoid valve terminal B and PCM terminal 2AB
Short circuit
•  If there is continuity, there is a short circuit. Repair or replace the wiring harness.
―  Purge solenoid valve terminal A and body ground
―  Purge solenoid valve terminal B and power supply
―  Purge solenoid valve terminal B and body ground