No.3 DOOR GLASS DOES NOT OPERATE USING THE REQUEST SWITCH[EXTERIOR OPEN/CLOSE FUNCTION]


id090397808800

3
Door glass does not operate using the request switch
POSSIBLE CAUSE
•  Keyless control module malfunction
•  PJB malfunction
•  Open circuit in wiring harness between request switch and keyless control module.
•  Any door or trunk lid/liftgate is open.
•  Key is inserted in steering lock.
•   Start knob is in a position other than LOCK position.

Diagnostic Procedure

Step

Inspection

Action

1
•  Verify the door lock/unlock operation by operating the request switch.
•  Does it operate normally?
Yes
Inspect the following parts, and repair or replace.
No
Go to the next step.
2
•  Verify the open/close condition of the doors and the trunk lid/liftgate.
•  Is the reason why they do not lock/unlock because a door or the trunk lid/liftgate is open?
Yes
The system is normal (When any door or the trunk lid/liftgate is open, the system does not operate).
No
Go to the next step.
3
•  Verify the start knob position, or if the key is in the steering lock.
•  Is the reason why the door lock/unlock does not operate because the start knob is in a position other than LOCK, or the key is inserted?
Yes
The system is normal (When the start knob is in a position other than LOCK, or the key is inserted in the steering lock, the system does not operate).
No
Go to the next step.
4
•  The door lock/unlock does not operate for reasons other than Steps 2 and 3 above.
Yes
Inspect the following parts, and repair or replace.
•  Wiring harness between the request switch and the keyless control module.
No
Reinspect for malfunction recurrence.If the malfunction is not corrected, repeat the procedure from Step 1.