UP SWITCH INSPECTION [DJVA-EL]


id051901288400

1.  Perform the following procedures.

(1)  Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [MZR 1.5, MZR 1.6].)
(2)  Disconnect the negative battery cable.
(3)  Remove the console. (See CONSOLE REMOVAL/INSTALLATION.)
(4)  Disconnect the selector lever component connector.
am3zzw00005087

2.  Inspect the continuity between the selector lever component terminals B and H.

am3uuw00002434

•  If there is any malfunction, replace the selector lever component. (See CVT (CONTINUOUSLY VARIABLE TRANSAXLE) SHIFT MECHANISM REMOVAL/INSTALLATION.)

Up switch specification

Test condition

Continuity

Selector lever is in the M range (+) side position
Continuity
Selector lever is not in the M range (+) side position
No continuity