NO.7 NO COOL AIR [MANUAL AIR CONDITIONER]
id0702c2812600
7
|
No cool air
|
DESCRIPTION
|
• Magnetic clutch does not operate.
|
POSSIBLE CAUSE
|
• Malfunction in PCM A/C cut control system
• Malfunction in climate control unit
• Malfunction in refrigerant pressure switch
• Malfunction in PCM (A/C signal)
• Malfunction in PCM (IG1 signal)
• Malfunction in A/C compressor
• Malfunction in A/C relay
• Malfunction in evaporator temperature sensor
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT AIR BLOW OUT
• Does air blow out?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 1 of troubleshooting indexes No.1 and 2.
|
||
2
|
INSPECT A/C COMPRESSOR OPERATION
• Start engine.
• Turn A/C switch and fan switch on.
• Does A/C compressor operate?
|
Yes
|
Go to Step 1 of troubleshooting index No.6.
|
No
|
Go to the next step.
|
||
3
|
INSPECT FOR DTC IN PCM
• Inspect for DTCs related to the PCM on-board diagnostic system.
• Are any DTCs displayed?
|
Yes
|
Go to appropriate inspection procedure.
|
No
|
Go to the next step.
|
||
4
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR ELSEWHERE
• Does cool air blow out when terminal 1L of climate control unit connector (24-pin, A/C signal) is grounded?
|
Yes
|
Replace the climate control unit, then go to Step 17.
|
No
|
Release short, then go to the next step.
|
||
5*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C SIGNAL CIRCUIT (BETWEEN REFRIGERANT PRESSURE SWITCH AND PCM) OR ELSEWHERE
• Test voltage at following terminal of refrigerant pressure switch.
Dual pressure type
Triple pressure type
• Is voltage approx. 12 V?
|
Yes
|
Go to Step 7.
|
No
|
Go to the next step.
|
||
6*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (BETWEEN REFRIGERANT PRESSURE SWITCH AND PCM) OR PCM
• Test voltage at A/C signal terminal of PCM.
• Is voltage approx. 12 V?
|
Yes
|
Repair wiring harness between PCM and refrigerant pressure switch, then go to Step 17.
|
No
|
Inspect the PCM, then go to Step 17.
(See PCM INSPECTION [MZR-CD 2.2].)
|
||
7
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN REFRIGERANT PRESSURE SWITCH, REFRIGERANT AMOUNT, OR ELSEWHERE
• Does cool air blow out when terminals A and B (dual pressure type) or B and C (triple pressure type) of refrigerant pressure switch connector are shorted?
|
Yes
|
Go to the Step 9.
|
No
|
Go to the next step.
|
||
8*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN REFRIGERANT PRESSURE SWITCH AND CLIMATE CONTROL UNIT) OR ELSEWHERE
• Test voltage at following terminal of climate control unit.
• Is voltage approx. 12 V?
|
Yes
|
Go to Step 10.
|
No
|
Repair wiring harness between refrigerant pressure switch and climate control unit, then go to Step 17.
|
||
9
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN REFRIGERANT PRESSURE SWITCH OR REFRIGERANT AMOUNT
• Inspect the refrigerant pressure switch.
• Is it okay?
|
Yes
|
If refrigerant amount is empty, replace condenser, vacuum refrigerant line more than 30 min by vacuum pump, and add refrigerant to specified level, then go to Step 17.
|
No
|
Replace the refrigerant pressure switch, then go to Step 17.
|
||
10
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN A/C CONTROL SIGNAL CIRCUIT (BETWEEN A/C RELAY AND PCM) OR ELSEWHERE
• Does cool air blow out when terminal E of A/C relay connector (A/C control signal) is grounded?
|
Yes
|
Release short, then go to the next step.
|
No
|
Go to Step 12.
|
||
11*
|
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN PCM OR WIRING HARNESS (BETWEEN A/C RELAY AND PCM)
• Test voltage at the A/C relay control signal terminal of PCM.
• Is voltage approx. 12 V?
|
Yes
|
Inspect the PCM, then go to Step 17.
(See PCM INSPECTION [MZR-CD 2.2].)
|
No
|
Repair wiring harness between A/C relay and PCM, then go to Step 17.
|
||
12*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN MAGNETIC CLUTCH OR ELSEWHERE
• Test voltage at the following terminal of magnetic clutch thermal protector.
• Is voltage approx. 12 V?
|
Yes
|
Inspect the magnetic clutch, then go to Step 17.
|
No
|
Go to the next step.
|
||
13
|
INSPECT FUSE
• Are A/C relay power supply fuses okay?
|
Yes
|
Go to the next step.
|
No
|
Replace the fuse, then go to Step 17. If fuse burns out immediately, go to the next step.
|
||
14
|
INSPECT WIRING HARNESS BETWEEN FUSE BLOCK AND A/C RELAY FOR LACK OF CONTINUITY
• Test voltages at following terminals of A/C relay.
• Are voltages approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between fuse block and A/C relay, then go to Step 17.
|
||
15
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C RELAY OR WIRING HARNESS (BETWEEN A/C RELAY AND MAGNETIC CLUTCH) AND EVAPORATOR TEMPERATURE SENSOR
• Turn A/C switch and fan switch on.
• Test voltage at the following terminal of A/C relay.
• Is voltage approx. 12 V?
|
Yes
|
Inspect wiring harness between A/C relay and magnetic clutch.
• If above wiring harness is OK, go to the next step.
• If above wiring harness malfunctions, repair wiring harness, then go to Step 17.
|
No
|
Replace the A/C relay, then go to Step 17.
|
||
16
|
INSPECT EVAPORATOR TEMPERATURE SENSOR
• Inspect the evaporator temperature sensor.
• Is it okay?
|
Yes
|
Go to the next step.
|
No
|
Replace the evaporator temperature sensor, then go to the next step.
|
||
17
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does cool air blow out? (Are the results of refrigerant system performance test okay?)
|
Yes
|
Troubleshooting completed. Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|