SECURITY LIGHT: NOT ILLUMINATED, DTC B10E6:12/- [IMMOBILIZER SYSTEM (ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM)]
id09021d905600
|
DTC |
Security light flashing pattern |
— |
Coil antenna power supply circuit malfunction |
|
|---|---|---|---|---|
|
M-MDS display |
Keyless control module |
B10E6:12 |
||
|
PCM |
— |
|||
|
DETECTION CONDITION
|
• Voltage higher than the specification (2.2—6.5 V) is detected for 0.05 s while the coil antenna power supply circuit is not active.
|
|||
|
POSSIBLE CAUSE
|
• Coil antenna connector or terminals malfunction
• Push button start connector or terminals malfunction
• Keyless control module connector or terminals malfunction
• Short to power supply in wiring harness between the following terminals:
• Push button start malfunction
• Coil antenna malfunction
• Keyless control module malfunction
|
|||
System Wiring Diagram
am6zzw00006141
|
Diagnostic Procedure
|
STEP |
INSPECTION |
ACTION |
|
|---|---|---|---|
|
1
|
INSPECT COIL ANTENNA CONNECTOR AND TERMINALS
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Disconnect the coil antenna connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 7.
|
|
No
|
Go to the next step.
|
||
|
2
|
INSPECT PUSH BUTTON START CONNECTOR AND TERMINALS
• Disconnect the push button start connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 7.
|
|
No
|
Go to the next step.
|
||
|
3
|
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
• Disconnect the keyless control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 7.
|
|
No
|
Go to the next step.
|
||
|
4
|
INSPECT COIL ANTENNA POWER SUPPLY CIRCUIT FOR SHORT TO POWER SUPPLY
• Coil antenna, push button start and keyless control module connectors are disconnected.
• Reconnect the negative battery cable.
• Measure the voltage at the keyless control module terminal 4Q (wiring harness-side).
• Is the voltage 2.2 V or more?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 7.
|
|
No
|
Go to the next step.
|
||
|
5
|
INSPECT PUSH BUTTON START
• Inspect the push button start.
• Is there any malfunction?
|
Yes
|
Replace the push button start, then go to Step 7.
|
|
No
|
Go to the next step.
|
||
|
6
|
VERIFY COIL ANTENNA MALFUNCTION
• Make sure to reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC from the keyless control module using the M-MDS.
• Disconnect the negative battery cable.
• Reconnect the negative battery cable.
• Verify the immobilizer system DTC using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the coil antenna, then go to the next step.
|
|
No
|
Go to Step 8.
|
||
|
7
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC from the keyless control module using the M-MDS.
• Disconnect the negative battery cable.
• Reconnect the negative battery cable.
• Verify the immobilizer system DTC using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the keyless control module and program the immobilizer system-related parts.
(See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM].)
(See IMMOBILIZER SYSTEM-RELATED PARTS PROGRAMMING [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM].)
Go to the next step.
|
|
No
|
Go to the next step.
|
||
|
8
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
|
No
|