DTC U2100:00 [INSTRUMENT CLUSTER]


id0902e8999600

DESCRIPTION

•  Configuration error
•  Configuration has not been performed
DETECTION CONDITION
•  Configuration setting has not been performed.
POSSIBLE CAUSE
•  Instrument cluster configuration not implemented.
•  Instrument cluster malfunction

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
PERFORM INSTRUMENT CLUSTER CONFIGURATION
•  Perform the instrument cluster configuration using the M-MDS.
•  Clear the DTC from the instrument cluster using the M-MDS.
•  Verify the instrument cluster DTC using the M-MDS.
•  Is the same DTC present?
Yes
Perform the instrument cluster configuration again, then go to the next step.
No
Go to Step 3.
2
VERIFY TROUBLESHOOTING COMPLETED
•  Clear the DTC from the instrument cluster using the M-MDS.
•  Verify the instrument cluster DTC using the M-MDS.
•  Is the same DTC present?
Yes
Replace the instrument cluster, then go to the next step.
No
Go to the next step.
3
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.