FRONT POWER WINDOW MOTOR INSPECTION


id091200001800


Auto-open/close Function For All Windows

1.  Disconnect the negative battery cable.

2.  Remove the inner garnish. (See INNER GARNISH REMOVAL/INSTALLATION.)

3.  Remove the front door trim. (See FRONT DOOR TRIM REMOVAL/INSTALLATION.)

4.  Disconnect the power window motor connector.

5.  Apply battery positive voltage and connect the ground to power window motor terminals E and F, and then inspect the power window motor operation.

am6zzw00006363

•  If the power window motor does not operate as indicated in the table, replace it.

Operation

Terminal

F

E

Open
B+
Ground
Close
Ground
B+

6.  Connect the battery positive voltage to power window motor terminal D and connect terminal C to ground.

7.  Operate the power window motor and measure the voltage at terminals A and B.

•  If there is any malfunction, replace the power window motor.
Voltage
Pulse: max. 5 V/min. 0 V


Auto-open/close Function for Driver-side


Front driver side

1.  Disconnect the negative battery cable.

2.  Remove the inner garnish. (See INNER GARNISH REMOVAL/INSTALLATION.)

3.  Remove the front door trim. (See FRONT DOOR TRIM REMOVAL/INSTALLATION.)

4.  Disconnect the power window motor connector.

5.  Apply battery positive voltage and connect the ground to power window motor terminals E and F, and then inspect the power window motor operation.

am6zzw00006363

•  If the power window motor does not operate as indicated in the table, replace it.

Operation

Terminal

F

E

Open
B+
Ground
Close
Ground
B+

6.  Connect the battery positive voltage to power window motor terminal D and connect terminal C to ground.

7.  Operate the power window motor and measure the voltage at terminals A and B.

•  If there is any malfunction, replace the power window motor.
Voltage
Pulse: max. 5 V/min. 0 V


Front passenger side

1.  Disconnect the negative battery cable.

2.  Remove the inner garnish. (See INNER GARNISH REMOVAL/INSTALLATION.)

3.  Remove the front door trim. (See FRONT DOOR TRIM REMOVAL/INSTALLATION.)

4.  Disconnect the power window motor connector.

5.  Apply battery positive voltage and connect the ground to power window motor terminals E and F, and then inspect the power window motor operation.

am6zzw00006364

•  If the power window motor does not operate as indicated in the table, replace it.

Operation

Terminal

F

E

Open
B+
Ground
Close
Ground
B+