NO.32 SCR SYSTEM WARNING INDICATION TURNED ON/[OVERFILLED AdBlue®] INDICATED IN DISPLAY [SKYACTIV-D 2.2]
id0103g1855200
32 |
SCR SYSTEM WARNING INDICATION TURNED ON/[OVERFILLED AdBlue®] INDICATED IN DISPLAY |
---|---|
DESCRIPTION
|
• The following messages are indicated in the display.
|
POSSIBLE CAUSE
|
• AdBlue® overfill
• Improper AdBlue® level
• PCM DTC is stored.
• Instrument cluster malfunction
|
Diagnostic Procedure
STEP |
INSPECTION |
RESULTS |
ACTION |
---|---|---|---|
1
|
INSPECT FOR MALFUNCTION DUE TO AdBlue® OVERFILL
• Verify the AdBlue® level.
Without multi-information display
With multi-information display
• Is the AdBlue® level 100% or more?
|
Yes
|
Drain the AdBlue® until the level reaches 65 to 100%.
Go to Step 5.
|
No
|
Go to the next step.
|
||
2
|
VERIFY PCM DTC
• Retrieve PCM DTCs using the M-MDS.
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Go to the next step.
|
||
3
|
INSPECT UREA LEVEL SENSOR
• Inspect the urea level sensor.
• Is the urea level sensor normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the urea level sensor, then go to Step 5.
|
||
4
|
INSPECT INSTRUMENT CLUSTER
• Inspect the instrument cluster.
• Is the instrument cluster normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning part according to the inspection results, then go to the next step.
|
||
5
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Has the malfunction symptom been eliminated?
|
Yes
|
Complete the symptom troubleshooting.(Explain repair contents to customer)
|
No
|
Repeat the inspection from Step 1.
|