UREA LEVEL SENSOR INSPECTION [SKYACTIV-D 2.2]
id0140z7825700
-
Note
-
• If measurements are taken with the vehicle on an uneven surface, a correct urea level cannot be detected because the urea tank could be tilted. When inspecting, take measurements with the vehicle on level ground.
• If the ambient temperature is low, the AdBlue® may have frozen and the AdBlue® level may not have been detected correctly. If the ambient temperature level is below freezing, take the measurement after the AdBlue® has defrosted.
PID/DATA Monitor Inspection
1. Park the vehicle on level ground.
2. Verify the ambient temperature.
-
Ambient temperature is below freezing
-
• After warming up the engine for approx.1 hour, go to the next step.
-
Ambient temperature is above freezing
-
• Go to the next step.
3. Connect the M-MDS to the DLC-2.
4. Switch the ignition ON (engine off).
5. Using the M-MDS, verify that the value of the ratio of remaining AdBlue® (PID: RRDC_AG_RMN) is 90% or less. (See ON-BOARD DIAGNOSTIC TEST [DOSING CONTROL UNIT (SKYACTIV-D 2.2)].)
-
90% or more
-
1. Switch the ignition off.
3. Using the M-MDS, verify that the PCM PID [RRDC_AG_RMN] is 90% or less, then go to the next step.
-
-
90% or less
-
• Switch the ignition OFF, and then go to the next step.
6. Add AdBlue® until the urea tank is completely full. (See AdBlue® REPLACEMENT [SKYACTIV-D 2.2].)
7. Switch the ignition ON (engine off).
8. Using the M-MDS, display the ratio of remaining AdBlue® (PID: RRDC_AG_RMN). (See ON-BOARD DIAGNOSTIC TEST [DOSING CONTROL UNIT (SKYACTIV-D 2.2)].)
9. Verify that the value of PID RRDC_AG_RMN is 90% or more.
-