DSC OFF SWITCH INSPECTION
id041500802000
Resistance Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the following parts:
3. Verify that the resistance between cluster switch terminals B and C is as indicated in the table.
am6zzw00016219
|
DSC OFF switch specification
|
Terminal |
Test condition |
Resistance (ohms) |
|
|---|---|---|---|
|
B—C
|
DSC OFF switch pressed
|
L.H.D.
|
0
|
|
R.H.D.
|
83.66—85.34
|
||
|
All switches released
|
1139.99—1163.01
|
||
LED Illumination Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the following parts:
3. Apply battery positive voltage to cluster switch terminal J, and connect terminal I to ground.
am6xuw00005613
|
4. Verify that the LED illuminates.