DTC C200B:25/C200B:62


id060200817100

DTC
C200B:25/C200B:62
Torque sensor
DETECTION CONDITION
•  C200B:25
―  Out-of-specification signal modulation is detected from torque sensor
•  C200B:62
―  Difference occurs between signals 1 and 2 from torque sensor
POSSIBLE CAUSE
•  Torque sensor malfunction
•  EPS control module malfunction


Diagnostic Procedure

Step

Inspection

Action

1
INSPECT TORQUE SENSOR USING M-MDS
•  Connect the M-MDS to the DLC-2.
•  Switch the ignition to ON (engine OFF).
•  Access “SS_TRQ1” and ”SS_TRQ2” PIDs.
•  Verify that the data monitor value changes when the steering wheel is turned.
―  Left: 0—positive
―  Right: 0— negative
•  Do the torque sensor signal values change in the same way?
Yes
Go to the next step.
No
Replace the steering gear and linkage (torque sensor), then go to the next step.
2
VERIFY THAT SAME DTC IS NOT PRESENT
•  Clear the DTC from the memory.
•  Is the same DTC present?
Yes
Repeat the inspection from Step 1.
If the malfunction recurs, replace the EPS control module.
No
Go to the next step.
3
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any other DTCs output?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.