DTC B102B:51 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
id09021c387300
DETECTION CONDITION
|
There is no record that an advanced key was programed (programming is never performed in past)
|
POSSIBLE CAUSE
|
• Advanced key is not programmed
• Keyless control module malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY NUMBER OF PROGRAMMED ADVANCED KEYS
• Perform the PID/data monitor inspection using the M-MDS.
• Is there a programmed advanced key?
|
Yes
|
Go to the next step.
|
No
|
Program a new advanced key, then go to the next step.
|
||
2
|
VERIFY TROUBLESHOOTING COMPLETED
• Clear the DTC from keyless control module memory using the M-MDS.
• Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|