METERING OIL PUMP INSPECTION [13B-MSP]
id0111e4801600
Metering Oil Pump Voltage Inspection
1. Disconnect the metering oil pump No.1 and No.2 connectors (2 terminals). (See METERING OIL PUMP REMOVAL/INSTALLATION [13B-MSP].)
2. Measure the voltage at terminal B using a tester.
ar8wzw00000748
|
Metering Oil Pump Resistance Inspection
1. Disconnect the metering oil pump No.1 and No.2 connectors (2 terminals). (See METERING OIL PUMP REMOVAL/INSTALLATION [13B-MSP].)
2. Measure the resistance between terminals A—B using a tester.
ar8wzw00000749
|
Oil Nozzle Inspection
1. Remove the oil nozzle. (See OIL NOZZLE REMOVAL/INSTALLATION [13B-MSP].)
2. Blow compressed air into area A while applying water to area B and verify that bubbles form on area B.
ar8wzw00000750
|
Specification
Compressed air (kPa {kgf/cm2, psi}) |
Condition |
---|---|
Below 200 {2.04, 29.0}
|
Bubbles not exist
|
350 {3.57, 50.8} or more
|
Bubbles exist
|
Oil Leakage Inspection
1. Verify that there is no oil leakage from the following metering oil pump system parts.