INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [13B-MSP]
id0140g1802200
Resistance Inspection
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [13B-MSP].)
2. Disconnect the negative battery cable.
3. Disconnect the MAF/IAT sensor connector.
4. Verify that the resistance between MAF sensor terminals D and E is as indicated in the table while blowing hot air gradually into the IAT sensor part built into the MAF sensor.
ar8uuw00001591
|
IAT sensor resistance
Air temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
-20 {-4}
|
13.6—18.4
|
20 {68}
|
2.21—2.69
|
60 {140}
|
0.493—0.667
|