NO.2 ABS WARNING LIGHT DOES NOT PERFORM SELF-DIAGNOSIS[AJ (3.0L Duratec)]


id0403b1804300

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT ABS CM
Turn the ignition switch off.
Disconnect the ABS connector.
Turn the ignition switch to the ON position.
Connect a jumper wire (with 10 A fuse) between the ABS HU/CM terminal H and ground
Does the ABS warning light illuminate?
Yes
Replace the ABS CM.
No
Go to the next step.
2
INSPECT ABS HU/CM TERMINAL H FOR OPEN CIRCUIT
Disconnect the instrument cluster connector.
Measure the resistance between the ABS HU/CM terminal H and the instrument cluster connector.
Is the resistance less than 5 ohms?
Yes
Replace the instrument cluster printed circuit.
No
Repair or replace the malfunctioning circuit.