INSTRUMENT CLUSTER INSPECTION
id092200800400
Speedometer
Using the Input/Output Check Mode (L3)
1. Inspect the speedometer using check code 12 of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[L3].)
Using the Input/Output Check Mode (AJ (3.0L Duratec))
1. Inspect the speedometer using check code "GAGE" of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[AJ (3.0L Duratec)].)
Using a Speedometer Tester
1. Adjust the tire pressure to the specification.
2. Using a speedometer tester, verify that the tester reading is as indicated in the table.
L3
Speedometer tester indication (km/h) |
Allowable range (km/h) |
---|---|
20
|
19—21
|
40
|
39—42
|
60
|
59—63
|
80
|
79—84
|
100
|
100—104
|
120
|
120—125
|
140
|
140—146
|
AJ (3.0L Duratec)
Speedometer tester indication (km/h) |
Allowable range (km/h) |
---|---|
20
|
19—22
|
40
|
38—43
|
60
|
58—64
|
80
|
78—86
|
100
|
97—107
|
120
|
117—128
|
140
|
136—149
|
Tachometer
Using the Input/Output Check Mode (L3)
1. Inspect the tachometer using check code 13 of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[L3].)
Using the Input/Output Check Mode (AJ (3.0L Duratec))
1. Inspect the tachometer using check code "GAGE" of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[AJ (3.0L Duratec)].)
Using M-MDS
1. Connect the M-MDS to the DLC-2 (16-pin).
atraaw00001883
|
2. Compare the data monitor item ISS_SRC (AJ (3.0L Duratec)) or RPM (L3) of PCM with the tachometer indication.
Fuel Gauge (L3)
1. Inspect the fuel gauge using check code 23 of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[L3].)
Fuel Gauge (AJ (3.0L Duratec))
1. Inspect the fuel gauge using check code "GAGE"of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[AJ (3.0L Duratec)].)
Water Temperature Gauge (L3)
1. Inspect the water temperature gauge using check code 25 of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[L3].)
Water Temperature Gauge (AJ (3.0L Duratec))
1. Inspect the water temperature gauge using check code "GAGE" of the input/output check mode. (See INPUT/OUTPUT CHECK MODE OF INSTRUMENT CLUSTER[AJ (3.0L Duratec)].)