Diagnostic procedure
STEP
|
INSPECTION
|
ACTION
|
|
---|---|---|---|
1
|
INSPECT ABS HU/CM POWER SUPPLY FUSE
• Is the ABS HU/CM ignition power supply fuse normal?
|
Yes
|
Go to the next step.
Inspect for a short to ground on blown fuse's circuit.
|
No
|
Repair or replace if necessary.
Install appropriate amperage fuse.
|
||
2
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY AND SHORT CIRCUIT
• Perform DTC inspection.
• Is any error message displayed regarding communication between the ABS HU/CM and WDS or equivalent?
|
Yes
|
If the communication error message is displayed even after inspecting according to the procedure displayed on the WDS or equivalent, go to step 6.
|
No
|
Go to the next step.
|
||
3
|
INSPECT FOR DTCs IN ABS HU/CM
• Have DTCs been stored in memory?
|
Yes
|
Perform the applicable DTC inspection.
(See DTC Table.)
|
No
|
Inspect the instrument cluster.
If the instrument cluster is normal, go to the next step.
If the instrument cluster malfunction repair the instrument cluster, go to the next step.
|
||
4
|
INSPECT BATTERY
• Is the battery voltage normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect the battery and charging system.
(See GENERATOR INSPECTION [L3].)
|
||
5
|
INSPECT CHARGING SYSTEM
• Is the battery voltage normal with electrical load (such as A/C, headlight) on and engine idling?
|
Yes
|
Go to the next step.
|
No
|
Inspect the charging system (such as drive belt tension and generator).
(See GENERATOR INSPECTION [L3].)
|
||
6
|
INSPECT ABS HU/CM IGNITION POWER SUPPLY SYSTEM (TERMINAL AK)
• Disconnect the ABS HU/CM connector.
• Turn the ignition switch to the ON position.
• Inspect the voltage of connector terminal AK.
Specification: approx. 8 V
• Is the voltage within the specification?
|
Yes
|
Replace the ABS HU/CM (open or short in ground circuit in the ABS HU/CM).
(See ABS HU REMOVAL/INSTALLATION.)
|
No
|
Repair the wiring harness between the ABS HU/CM and ground.
|
||
7
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM GROUND FOR CONTINUITY
• Turn the ignition switch to the LOCK position.
• Is there continuity between connector terminal A and ground?
|
Yes
|
If a malfunction error message is displayed on WDS or equivalent in Step 1 inspection, go to the next step.
If a malfunction error message is not displayed on WDS or equivalent in Step 1 inspection, troubleshooting is completed.
|
No
|
Repair the wiring harness between the ABS HU/CM and ground.
|
||
8
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY
• Is there continuity between connector terminal AQ and DLC-2?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
||
9
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO POWER SUPPLY
• Is the voltage approx. 12 V at connector terminal AQ?
|
Yes
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
No
|
Go to the next step.
|
||
10
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO GROUND
• Is there continuity between connector terminal AQ and DLC-2?
|
Yes
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
No
|
Replace the ABS HU/CM (communication circuit malfunction in ABS HU/CM).
(See ABS HU REMOVAL/INSTALLATION.)
|
||
|