Test 8








Test 8:

Selector dial Function button Blower
22 °C "d" "f"

- Blower running at max. speed (6th stage).
- Monovalve cycling (every 4-5 seconds). At room temperatures >25 °C refer to "Notes: 3." as dec]scribed at the beginning of this information.
- Compressor switched off.
- Main air flap open (fresh air).
- Recirculating pump running.






Air distribution