Test 8
Test 8:
Selector dial Function button Blower22 °C
"d"
"f"
-
Blower running at max. speed (6th stage).
-
Monovalve cycling (every 4-5 seconds). At room temperatures >25 °C refer to "Notes: 3." as dec]scribed at the beginning of this information.
-
Compressor switched off.
-
Main
air flap open (fresh air).
-
Recirculating pump running.
Air distribution