Test 1
TEST 1:
Test 1:
Main Air Flap - Closed:
Test Conditions:
Selector Dial:
22°C
Function Button:
"e"
Blower:
"AUTOM"
Test Results/Observations:
-
Monovalve closed.
-
Recirculating pump not running.
-
Compressor switched off.
-
Main air flaps closed (approx. 20 % fresh air, 80 % recirculating air).
-
Blower not running.