Test 10
TEST 10:
Test 10:
Main Air Flaps - Open:
Test Conditions:
Selector Dial:
Optional
Function Button:
"a"
Blower:
Optional
Test Results/Observations:
-
Blower running at max. speed (6th stage).
-
Monovalve opened.
-
Recirculating pump running.
-
Compressor switched on at outside temperatures > 2°C.
-
Main air flaps open (fresh air).