Manuals through 2025 now available!
Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.
LEMON is the spiritual successor to CHARM, I recommend you try it!
Link:
lemon-manuals.la or
lemon-manuals.org.ua
(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)
Or, hide this message:
temporarily or
permanently
Test 12
TEST 12:
Test 1:
Test Conditions:
Selector Dial:
22°C
Function Button:
"e"
Blower:
"AUTOM"
Test Results/Observations:
-
Monovalve closed.
-
Recirculating pump not running.
-
Compressor switched off.
-
Main air flaps closed (20% fresh air, 80% recirculating air).
-
Blower not running.