Test 8
TEST 8:
Test 7:
Main Air Flaps - Open:
Test Conditions:
Selector Dial:
26°C
Function Button:
"d"
Blower:
"f"
Test Results/Observations:
-
Blower running at Max. (6th stage).
-
Monovalve cycling (every 4-5 seconds).
-
Compressor switched off.
-
Center nozzle flap closed (no air from center nozzle).
-
Main air flaps open (fresh air).
-
Recirculating pump running.