Ignition Monitoring Shunt: Testing and Inspection
Ignition Switch (M/T) Circuit:
1.
With the
ignition switch in the START position, measure the Voltage at ECM terminal 51--should be 8 Volts or more.
2.
Verify ECM terminal 71 continuity to ground.
3.
Verify ECM terminal 51 continuity to the
ignition switch START circuit.