Load Test
Service Adjustment Procedures:
1.
Connect a load tester to the battery.
2.
Load the battery at
15 Amps for
15 Seconds to remove surface charge.
3.
Load the battery at the recommended discharge rate.
4.
Read voltage after
15 Seconds and then remove the load.
5.
If the voltage is not maintained at the minimum voltage in the LOAD TEST CHART throughout the test, the battery should be replaced.