Operation CHARM: Car repair manuals for everyone.

Air Flow Meter/Sensor

OUTPUT FREQUENCY
(Reading taken using scan tool)
At 750 RPM 40 - 60 Hertz
At 2,000 RPM 85 - 105 Hertz
Racing engine should increase the frequency

VOLTAGE SPECIFICATIONS
Terminal 4 System Voltage
Terminal 3 4.8 - 5.2 Volts