Diagnosis
2. SCAN TOOL COMMUNICATION WITH ECM IS NOT POSSIBLETROUBLESHOOTING HINTS
The most likely causes for this case:
- Malfunction of ECM power supply circuit.
- Malfunction of the ECM.
- Open circuit between ECM and data link connector.
DIAGNOSIS
STEP 1. Check the harness wire between the data link connector C-69 and the ECM connector C-55.
NOTE: After inspecting the intermediate connectors C-1O and C-16, inspect the wire.
If the intermediate connectors C-10 and C-16 are damaged, repair or replace them. Then confirm that The malfunction symptom is eliminated.
C10
C16
- If the wire between the data link connector C-69 and the ECM connector C-55 is not damaged, go to Step 2.
- If the wire between the data link connector C-69 and the ECM connector C-55 is damaged, repair it. Then confirm that the malfunction symptom is eliminated.
STEP 2. Check harness connector C-55 at the ECM for damage.
- If harness connector 0-55 is damaged, repair or replace it.
- If harness connector 0-55 is in good condition, refer to INSPECTION PROCEDURE 26 - Power Supply and Ignition Switch-IG System. Then confirm that the malfunction symptom is eliminated.