Transmission Temperature Sensor/Switch: Testing and Inspection

A/T FLUID TEMPERATURE SENSOR CONTINUITY CHECK





1. Remove the A/T fluid temperature sensor.
2. Measure the resistance between terminals No.1 and No.2 of the A/T control solenoid valve assembly connector.





Standard value

3. If the A/T fluid temperature sensor resistance is not consistent with the fluid temperature replace A/T fluid temperature sensor.

NOTE: The N range indicator light on the combination meter flashes when the temperature reaches approximately 125°C (257°F) or higher, and then stops flashing when the temperature drops below approximately 115°C (238°F).