Alternator: Testing and Inspection
Generator Pulley InspectionGENERATOR PULLEY INSPECTION
One-Way Clutch Pulley Check
CAUTION: Be careful not to damage rotor
NOTE: Secure rotor using suitable tool and a rolled shop towel.
1. Check for locking; (Outer ring is turned clockwise when viewed from front.)
- If it rotates in both directions replace pulley.
2. Check for dragging. (Outer ring is turned counterclockwise when viewed from front.)
- If it locks or unusual resistance is felt replace pulley.