Work Procedure
ADDITIONAL SERVICE WHEN REPLACING SLIDING DOOR CONTROL UNIT
Work Procedure
1. INITIALIZATION
1.Operate automatic sliding door open/close switch or automatic sliding door one-touch open/close switch, and the automatic open function operates. (Perform open operation first in the non-initialized status regardless of sliding door position)
2.After sliding door is stopped in the fully open position, operate automatic sliding door open/close switch or automatic sliding door one-touch open/close switch, and the automatic close function operates.
3.Check for noise or malfunctioning during operation.
4.Check that automatic sliding door warning buzzer operates.
CAUTION:
Never touch sliding door, or allow foreign materials to be pinched in door, when performing automatic open/close operation of sliding door, until it is in the fully closed or fully open position.
- WORK END