CAN
ASD-R BRANCH LINE CIRCUIT
Diagnosis Procedure
1. CHECK CONNECTOR
1.Turn the ignition switch OFF.
2.Disconnect the battery cable from the negative terminal.
3.Check the terminals and connectors of the sliding door control unit RH for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES- GO TO 2.
NO- Repair the terminal and connector.
2. CHECK HARNESS FOR OPEN CIRCUIT
1.Disconnect the connector of sliding door control unit RH.
2.Check the resistance between the sliding door control unit RH harness connector terminals.
Is the measurement value within the specification?
YES- GO TO 3.
NO- Replace the body No. 2 harness.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the sliding door control unit RH. Sliding Door Control Unit.
Is the inspection result normal?
YES (Present error)-Replace the sliding door control unit RH. RH.
YES (Past error)-Error was detected in the sliding door control unit RH branch line.
NO- Repair the power supply and the ground circuit.